SFire-Safety-Security-Qality-Provider-qppak

Gent by Honeywell

Qppak updated 2020-2-27

Conventional and Addressable Fire Alarm Systems By Gent, Honywell, Xenex.

1: Gent Conventional Fire Alarm Panel

2: Manual call points Conventional Fire alarm systems gent by Honeywell

3: Conventional Fire alarm systems Smoke Detectors

4: Conventional Fire alarm systems Bells

5: Sounders Conventional Fire alarm system

6: Gent fire alarm system reset code, silent fire alarm code

Panel Conventional

1: From control panels through to manual call points, detectors, bells, door releases and sounders, Honeywell Gent provides a cost effective conventional fire detection system scalable for sites of all types.

With the Gent Xenex control panel at its hub, Gent can cover up to eight zones.

Integrated with the low-current S-Cubed range of sounders incorporating sound, speech and strobe in a single device, Gent ensures a site has high levels of coverage with above average response rates during an emergency situation.

Gent-By-Honeywell-Conventional-Fire-Alarm-Panel

2: The Gent Xenex range of conventional fire detection and alarm panels is a highly cost effective option for small building premises requiring coverage for up to eight zones. Certified to EN54 Parts 2 and 4, the Gent Xenex panel contains integral power supply and battery standby for up to 72hrs.

With up to eight alarm sounder circuits, repeat panel output, remote evacuation control and one-man test and commissioning Gent Xenex is a leader in conventional panel technology.

Conventional Smoke Detector

3: The ES Detect range is non-addressable detectors specifically designed for operation on conventional systems.

The range includes a fixed heat detector, fixed heat for Class B, rate of rise detector and an optical smoke detector.

Conventional Heat Detector

4: The Multi-functional Detector uses a state of the art optical chamber and heat element combined with sophisticated algorithms to provide quick and accurate detection of fires.

The combination of optical and heat detection provides a faster response to ‘real fire’ situations, while at the same time reducing the risk of unwanted environmentally generated alarms.

Conventional Smoke Detector

5: The Optical Smoke Detector uses a state of the art optical chamber combined with an application specific integrated circuit ( ASIC ) to provide quick and accurate detection of fires.

A combination of the unique chamber design and other technically advanced features will significantly extend the service intervals before cleaning of the detector becomes necessary.

Conventional Rate of Rise Heat Detector

6: The Heat Detector uses a state of the art heat element combined with an application specific integrated circuit (ASIC) to provide quick and accurate detection of fires.

The detector incorporates both rate of rise and static elements and is suitable for all areas where the ambient conditions do not normally exhibit rapid changes in temperature.

Fixed Temperature Heat Detectors Conventional

7: The Vision range of Fixed Temperature Heat Detectors have been produced using the latest in manufacturing technology and supplied with an array of installer-friendly advanced features, making them ideal for all your conventional fire detection requirements.

GENT 2 Zone Conventional Panel

  1. 2 Zone Conventional Panel features
  2. Gent Xenex Description 2 Zone fire alarm systems
  3. Gent Xenex Main Features 2 Zone fire alarm systems

Gent Xenex Features

1: It deploys devices on conventional radial wiring layouts using standard 2-core cable

2: Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors, sounders, strobes, and bells

3: Sounder options include shallow base, deep base and bedhead sounder types

Gent Xenex Description

GENT 2 ZONE CONVENTIONAL PANEL provides owners of small building premises with quality protection equipment at an economical price.

The Gent Xenex panel complies fully with the European standard EN 54 Parts 2 and 4 and can be used on installations meeting BS 5839-1.

Each panel contains its own integral power supply and battery support for up to eight alarm sounder circuits, two auxiliary relay contacts, a zone disablement facility and a one man test and commission facility, all simplifying system design, installation and commissioning.

Gent Xenex Main Features

1: Gent Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable

2: Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells

3: Sounder options include shallow base, deep base and bedhead sounder types

4: For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available

5: Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated

6: Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software

GENT 4 Zone Conventional Panel

4 Zone Key Features Gent Fire Alarm Systems

1: Gent Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable

Device options include a full range of smoke detectors optical, beam and duct types), Heat detectors, Sounders, strobes, and bells.

2: Sounder options include shallow base, deep base and bedhead sounder type

Gent 4 Zone Description

GENT 4 zone conventional panel

1: The Gent Xenex conventional fire detection and alarm system from Gent provides owners of small building premises with quality protection equipment at an economical price.

2: The Gent Xenex panel complies fully with the European standard EN 54 Parts 2 and 4 and can be used on installations meeting BS 5839-1.

3: Each panel contains its own integral power supply and battery support for up to eight alarm sounder circuits, two auxiliary relay contacts, a zone disablement facility and a one man test and commission facility, all simplifying system design, installation and commissioning.

Main Features Gent Xenex

1: Gent Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable

Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells.

2: Sounder options include shallow base, deep base and bedhead sounder types

For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available.

3: Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated.

4: Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software

GENT 8 Zone Conventional Panel

Gent Xenex 8 Features

1: Gent Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable

2: Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rising types), sounders, strobes, and bells

Gent Xenex Description

1: GENT Xenex 8 zone conventional panel

2: The Gent Xenex conventional fire detection and alarm system from Gent provide owners of small building premises with quality protection equipment at an economical price.

3: The Gent Xenex panel complies fully with the European standard EN 54 Parts 2 and 4 and can be used on installations meeting BS 5839-1.

4: Each panel contains its integral power supply and battery support for up to eight alarm sounder circuits, two auxiliary relay contacts, a zone disablement facility and a one-man test and commission facility, all simplifying system design, installation, and commissioning.

Gent Xenex Main Features 8 Zone

1: Gent Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable

2: Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rising types), sounders, strobes, and bells

3: Sounder options include shallow base, deep base and bedhead sounder types

4: For installations where a high degree of weatherproofing is required, IP55 rated sounders, sirens and bells are available

5: Common accessories such as manual call points (standard IP54 rated or key-operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated

6: Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software

GENT Conventional Call point

1: Gent Manual call points from Honeywell Gent are easy and safe to operate, with no hammer required. Fully compliant with EN 54-11, each point is manufactured from ABS and both have a break glass and resettable element.

2:For areas susceptible to inadvertent operation.

Call Point Description

1: GENT Conventional Call Point

2: Manual call points from Honeywell Gent are easy and safe to operate, with no hammer required. Fully compliant with EN 54-11, each point is manufactured from ABS and both have a break glass and resettable element.

3: For areas susceptible to inadvertent operation – such as sports halls – a stronger, clear polycarbonate cover version is available.

Gent Conventional Smoke Detector

Smoke Detector Features

1: Uniform response sensitivity of the detector for all different types of fire for the multi-sensor detectors

2: Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences

3: Automatic adaptation to varying environmental influences

Smoke Detector Description

1:Gent Conventional Smoke Detector

2:The new ES Detect range (S Quad conventional) has been developed to operate with the Gent Xenex panel.

3:The ES Detect range replaces the Vision 20/20 range.

4:The Gent detector is a scattered-light smoke detector for reliable early detection of fires.

5:Fire detector with decentralized intelligence, automatic function self-test, automatic environmental adaptation, alarm and operating data storage and alarm display.

6:A remote indicator can also be connected.

Smoke Detector Main Features

1: Uniform response sensitivity of the detector for all different types of fire for the multi-sensor detectors

2: Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences

3: Automatic adaptation to varying environmental influences

4: Electronic compensation of long-term influences of contamination or aging

Gent Conventional Heat Detector

Gent Conventional Heat Detector Key Features

1: Uniform response sensitivity of the detector for all different types of fire for the multi-sensor detectors

2: Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences

3: Automatic adaptation to varying environmental influences

Gent Conventional Heat Detector

Description

Gent Conventional Heat Detector Description

The new ES Detect range (S Quad conventional) has been developed to operate with the Gent Xenex panel.

The ES Detect range replaces the Vision 20/20 range.

The heat detector is an automatic heat detector with fast semiconductor sensor for reliable detection of fires with distinctive heat.

Fire detector with decentralized intelligence, automatic function self-test, alarm and operations data storage and alarm display.

A remote indicator can also be connected.

Heat Detector Main Features

1: Uniform response sensitivity of the detector for all different types of fire for the multi-sensor detectors

2: Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences

3: Automatic adaptation to varying environmental influences

4: Electronic compensation of long-term influences of contamination or aging

Gent Conventional Sounder

Key Features Gent Conventional Sounder

Approved to EN54-3

Superior sound output and low current consumption

32 tones all approved to EN54-3

Adjustable volume settings

Two stage sounders enable alert and alarm sequences to be set for phased evacuation

Synchronized sound output

Description Gent Conventional Sounder

Gent Conventional Sounder is a high-quality device designed to alert building occupants of an emergency.

The product Gent Conventional Sounder features a new folded horn design that provides an outstanding sound output at a low current draw. With its modern design, global tone set and extensive installer-friendly features, the sounder is the logical choice for specifies, installers and distributors.

Gent Conventional Sounder Key Features

1: Approved to EN54-3

2: Superior sound output and low current consumption

3: All 32 tones approved to EN54-3

4: Adjustable volume settings

5: Two-stage sounders enable alert and alarm sequences to be set for phased evacuation

6: Synchronized sound output

Gent Vigil on Plus 1-4 Loop Addressable Control Panel

1: Integral EN54-4 PSU and battery standby for 24 hours (4 loop panel only)

2: PC based commissioning tools allow complex fire plans to be configured

3: Advanced loop card technology allows for system status monitoring and diagnostics

4: Flexible programming options are available at the panel

5: Extended event log using flash memory card

Description Gent Vigil on Plus 1-4 Loop Control Panel

Gent Vigil on Plus 1-4 Loop Control Panel with 1 Loop Card

Fully compatible with Honeywell Gent’s innovative S-Quad range – a combined Multi-Sensor range with speech, sounder and EN54-23 Visual Alarm devices in one intelligent unit.

The Vigil on Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop, the repeated panel provides a cost-effective solution with minimum requirements for cabling and installation.

Gent Vigil on Plus 1-4 Loop Control Panel Key Features

1: Integral EN54-4 PSU and battery standby for 24 hours 1-4 loop control

2: Vigil on advanced sensing technology and powerful processing in the panel quickly and identifies real fires

3: Advanced loop card technology allows for system status monitoring and diagnostics

Generic Photoelectric Addressable Smoke Alarm Detector

1: Warns you of intending fire

2: Doesn’t send off false alarm

3: Battery Powered 9V

4: Led indicator

5: Low-sensitivity warning

6: Low-battery warning

7: Utilizes both ionization and photoelectric smoke sensors

8: Smart sensing technology

9: EZ access battery door

10: Two AA batteries included

11: Loud 85db alarm

12: Meets UL217 standard for dual sensor home smoke detectors

13: Test / Silence button<

Generic Photoelectric Addressable Smoke Description

Wireless Smoke Detector gives you early warning of fires.

It detects smoke by a couple of infrared diodes and the alarm will sound off immediately.

FEATURES OF GENERIC SMOKE DETECTOR

1: Photoelectric smoke sensing detector

Quick & easy installation, no wiring required

High sensitivity- responds to all standard fires

Loud alarm-85 decibels

Eco-friendly

Battery lasts over a year

Test button simulates smoke alarm

2: Generic Smoke Detector 9V Battery Powered

3: Led indicator

4: Low-sensitivity warning

5: Low-battery warning

6: Test Button

7: SMD Circuit board design

8: Gent Panel Battery Included

9: Utilizes both ionization and photoelectric smoke sensors

10: Smart sensing technology

11: EZ access battery door

12: Two AA batteries included

13: Loud 85db alarm

14: Meets UL217 standard for dual sensor home smoke detectors

15: Test/silence button

Gent S4-720 S-Quad Optical Addressable

Heat Detector Gent S4-720 S-Quad Optical Addressable

Gent S4-720 Key Features

1: Each sensor element has sensitivity settings which can be adjusted to suit the environment / application and can be programmed for different time periods during the day or night

>

2: Repeat fire LED output as standard (if monitored input not used)

3: Operational LED blinks On/Off option

4: Monitored Input – which can be Fire, Fault or Supervisory

Gent S4-720 Description

Gent S4-720 Heat Detector Description

Gent S Quad Detectors come up as a new concept in fire detection. The sensor is completely reliable that offers you quick response to fire and ensures exceptional computing power.

The risk of false alarm is quite low, as this fire detection device is made to make life safe and easy.

If you are looking for the most innovative option and genuine solution to fire detection, you must consider purchasing this product.

With the improved speed and integrity of fire detection, this device will serve your purposes in the best possible manner.

Coupled with integral sounder and speech capability, everything used in the device is of the next level and this is what makes Gent S Quad Detectors a great choice for fire detection alarm.

Gent S4-720 Heat Detector Features

1: Gent S4-720 Heat Detector Key Features

2: The sensor element comes with sensitivity setting that can be adjusted to match the environment and can be used for different time periods during day or night according to your requirements.

3: Standard repeat fire LED output

4: Comes with on/off option as an operational LED blink.

5: Monitored Input – which can be Fire, Fault or Supervisory

GENT S4-34845 CALL POINT

GENT S4-34845 CALL POINT WITH GLASS COVER

Technical Data GENT S4-34845

Case

ABS engineering plastic

Color

Red

Emission

BS EN61000-6-3:2001 Residential, Commercial & Light Industry Class B limits

Operating Temperature

-25 to 70°C

Operating Voltage

35V – 41V

Standard

EN54: Part 11: 2001

GENT S4-34845 Description

GENT S4-34845 CALL POINT

GENT S4-34845 Technical Data

Case

ABS Engineering Plastic

Color

Red

Emission

BS EN61000-6-3:2001 Residential, Commercial & Light Industry Class B limits

Operating Temperature

-25 To 70°C

Operating Voltage

35V – 41V

Standard

EN54: Part 11: 2001

Terminals

2.5mm cubed maximum

Testing

The mechanism and operation of the MCP is tested by using a test key

Dimensions ( WxHxD )

88mm x 88mm x 21mm

Weight

110g

Fire Alarm Code

Gent Conventional Fire Alarm Panel Access Code 123 Press Silence Alarms Button.

Only the fire alarm devices Sounder OR Bell will stop sounding the Fire alarm panel buzzer will continue sounding.

Press the Cancel Buzzer Button fire alarm panel internal buzzer stop sounding.

Fire-Alarm-Code
Fire-Safety

Safety Security more info

CCTV Camera Systems

Fire Alarm more info

Cooper Menvier JSB Fire Alarm Systems more info

Fire Extingisher more info

C-Tec Fire Alarm System more products

Gent Fire Alarm System more products

Signage more info

Time-Attendance more info